Current Issue

Robert BoguskiAre we headed toward Singularity? Or just more PowerPoints?

Thus says IPC:

The Hermes Standard Initiative is happy and glad to announce that IPC has confirmed to recognize The Hermes Standard to be the successor to “the SMEMA Standard” IPC-SMEMA-9851, which has been the only globally accepted and broadly established standard for machine to machine communication in SMT with regard to PCB handover. Accordingly, The Hermes Standard was assigned an IPC naming code: It can now officially be referred to as IPC-HERMES-9852.

This strong acknowledgment means a lot for further enhancements of the global footprint and acceptance of The Hermes Standard. With The Hermes Standard having shown an impressively fast start from early drafts to worldwide awareness, it is now entering the second stage in global market penetration.

Read more: Better Living Through Data

David BernardWhen nondestructive methods are preferred, leverage the x-ray.

Read more: Bare Board X-ray Inspection: Start at the Base

David Bernard

What are void calculation tools telling you?

Although most will justify the cost of acquiring x-ray inspection capability for their facility based on the need for checking the reflow under BGAs, I suggest that, in terms of justification, looking for issues under QFNs could arguably be as important, if not more so. Use of quad flat no-lead (QFN) packages has become ubiquitous, and hidden QFN joints cannot be seen optically, post-reflow. Such joints may be more important to consider investigating as a matter of course because of the shape and design of the package and connections.

QFNs are planar objects and often contain a large central termination in the center (as a ground and/or for heat removal) with smaller I/O connections around the edges (FIGURE 1). In such a configuration, a relatively large volume of solder in the center will outgas during reflow. With the package flat to the board, and limited available pathways for the gas to exit, this may impinge upon how successfully gas is removed. Anecdotally at least, this would seem to be why there usually appears to be some level of voiding in the central terminations of most QFNs I have seen.

Read more: Voiding Under QFN Central Terminations

David BernardThe target style of the x-ray tube impacts magnification, resolution and quantity.

In last month’s column I explained the impact a transmissive or reflective target style of x-ray tube will have on the available magnification of an x-ray system. The difference between the two target types is shown in FIGURE 1. Not just the magnification is altered by the choice of target, however. The focus, or resolution, of the tube, as well as the flux, or quantity of x-rays, that the tube produces will also be affected. This is caused by the x-ray tube settings.

 

 

Read more: X-ray Focus and Power – Transmissive and Reflective Targets

Page 234 of 246